The condition where an indoor air conditioning unit accumulates ice on its evaporator coil during warm weather operation is a common HVAC malfunction. This ice buildup restricts airflow and diminishes the unit’s capacity to cool the designated space. As an example, a homeowner might observe that their central air system is running continuously but failing to lower the indoor temperature, coupled with visible ice formation on the indoor unit.
Addressing this issue promptly is crucial for maintaining energy efficiency and preventing potential damage to the HVAC system. Untreated icing can lead to compressor failure, ductwork damage from condensation, and increased energy consumption as the system struggles to meet the thermostat setting. Historically, this problem was often misdiagnosed, leading to unnecessary repairs or replacements; however, modern diagnostic techniques allow for accurate identification and resolution of the root cause.
The primary causes, diagnostic procedures, and preventative measures related to this specific malfunction will be detailed below. This includes examining issues such as restricted airflow, refrigerant leaks, and malfunctioning components that contribute to the formation of ice on the evaporator coil during the summer months.
1. Restricted Airflow
The tale of a frozen air handler often begins with a silent culprit: restricted airflow. Imagine the air handler as a diligent worker, constantly drawing in air to cool it. When that air supply is choked, the worker labors in vain, the cooling process becomes strained, and the consequences manifest as ice. The connection is a matter of physics: reduced airflow over the evaporator coil causes the refrigerant inside to become excessively cold. This super-cooled coil then chills the moisture in the already limited airflow, causing it to freeze and accumulate as ice. A homeowner, diligently paying energy bills, might notice an alarming rise in costs despite the house remaining uncomfortably warm. The problem, often unseen, is a dirty air filter starving the air handler.
Consider the case of a small business owner whose employees began complaining about the stifling heat one summer. Maintenance staff, initially stumped, eventually discovered that construction debris from a recent renovation had clogged the return air vents. This blockage severely limited the amount of warm air reaching the cooling coils. The reduced airflow, coupled with the unit’s relentless attempt to cool, resulted in a thick layer of ice enveloping the air handler. This real-world scenario emphasizes the crucial role of unobstructed airflow in maintaining system efficiency. Regular filter changes, ensuring vents are free from obstructions, and proactive duct cleaning are not mere suggestions; they are necessities for preventing this icy crisis.
Ultimately, restricted airflow is not just a contributor to the problem; it is frequently the initiating factor. Recognizing the signs reduced airflow from vents, rising energy bills, and a persistently warm indoor environment empowers individuals to take preventative action. By prioritizing regular maintenance and addressing potential airflow obstructions promptly, homeowners and business owners can circumvent the consequences of a frozen air handler and ensure reliable, efficient cooling throughout the summer months. The narrative is clear: unrestricted airflow is paramount to preventing an air handler from succumbing to the summer’s heat with an icy response.
2. Refrigerant Leaks
The story of an air handler freezing in the summer often involves a silent, insidious villain: a refrigerant leak. This gradual loss of refrigerant disrupts the delicate balance within the cooling system, leading to a chain of events that culminates in ice formation. Its a tale of diminishing capacity and escalating problems, all stemming from a breach in the sealed system.
-
Reduced Cooling Capacity
A refrigerant leak means less refrigerant is available to absorb heat from the indoor air. As the system struggles to meet the thermostat setting, it runs longer and harder. The evaporator coil, now starved of the proper refrigerant charge, becomes abnormally cold. This extreme temperature drop causes moisture in the air to freeze rapidly on the coil’s surface. For instance, a family returns from vacation to find their house sweltering, despite the air conditioner running continuously. The culprit, unbeknownst to them, is a slow refrigerant leak that has gradually degraded the system’s ability to cool, leading to ice formation and eventual shutdown.
-
Lower Evaporator Coil Temperature
The core function of refrigerant is to absorb heat and cycle it outside. A reduction in refrigerant translates to a lower pressure within the system and, consequently, a drastically colder evaporator coil. This super-cooled coil acts as an ice magnet, drawing moisture from the air and solidifying it. Consider a commercial building where the AC struggles on hot afternoons. Technicians discover a small leak at a fitting, causing the refrigerant to slowly escape. The reduced pressure results in the evaporator coil dropping to sub-freezing temperatures, initiating a cycle of ice buildup that eventually impairs the entire system’s efficiency.
-
System Imbalance and Component Stress
A refrigerant leak throws the entire HVAC system out of balance. The compressor, forced to work harder to compensate for the diminished refrigerant, experiences increased wear and tear. Other components, such as the expansion valve, also face undue stress. A homeowner, noticing unusual noises coming from the outdoor unit, ignores them until the entire system grinds to a halt. Later, a technician reveals that a refrigerant leak caused the compressor to overwork, leading to its premature failure. The imbalance initiated by the leak cascaded through the system, causing widespread damage.
-
Ice Formation and Airflow Obstruction
The ice that forms on the evaporator coil due to low refrigerant acts as an insulator, further reducing the systems ability to cool and exacerbating the original problem. The airflow is restricted, causing the system to work even harder, consuming more energy and potentially leading to additional component failures. A family hosting a summer barbecue finds their air conditioning struggling to keep up. They soon discover a layer of ice has formed on the indoor unit. The reduced airflow, caused by the ice, renders the system ineffective, turning their outdoor gathering into an uncomfortable indoor affair.
The refrigerant leak is not merely a cause; its a catalyst for a cascade of problems, each contributing to the air handler’s icy demise. From reduced cooling capacity to component stress, the consequences are far-reaching. Addressing these leaks promptly is not simply a matter of topping off the refrigerant; it requires a thorough inspection to locate and repair the source of the leak, restoring the system’s equilibrium and preventing a recurrence of the freezing phenomenon.
3. Dirty Air Filter
The narrative of an air handler succumbing to ice in the summer months often features a seemingly innocuous antagonist: the dirty air filter. This seemingly minor component, when neglected, can initiate a chain of events culminating in a system-wide freeze. The connection is a matter of airflow, or rather, the lack thereof. The air filter’s purpose is to cleanse the air circulating through the HVAC system, capturing dust, pollen, and other particulate matter. When this filter becomes saturated with debris, it restricts the passage of air, creating a bottleneck that directly impacts the evaporator coil’s temperature. As an example, a family returning from a beach vacation found their home unusually warm. The air conditioner was running, but the airflow from the vents was weak. The culprit? A severely clogged air filter, packed with sand and dust carried in from their trip. This restriction caused the evaporator coil to freeze, effectively shutting down the cooling process.
The significance of a clean air filter extends beyond mere air quality; it is intrinsically linked to the functionality and longevity of the entire HVAC system. Restricted airflow forces the air handler to work harder, increasing energy consumption and placing undue stress on components like the blower motor and compressor. Furthermore, the reduced airflow over the evaporator coil leads to a drop in temperature, causing moisture to freeze on the coil’s surface. This ice buildup further restricts airflow, exacerbating the problem in a self-perpetuating cycle. Consider a small office building where the maintenance team overlooked the routine filter changes. Over time, the filters became laden with dust and grime, severely limiting airflow. The resulting ice formation on the air handlers not only reduced cooling efficiency but also led to water damage as the ice melted, necessitating costly repairs to the ceiling and surrounding areas.
In conclusion, the dirty air filter is far more than a minor inconvenience; it is a critical factor in preventing an air handler from freezing during the summer. Regular filter replacement, typically every one to three months depending on usage and environmental factors, is a simple yet effective preventative measure. By ensuring unobstructed airflow, property owners can safeguard their HVAC systems, maintain energy efficiency, and prevent the costly consequences of a frozen air handler. The lesson is clear: a clean air filter is an investment in the long-term health and performance of the entire cooling system.
4. Coil Temperature
The saga of an air handler’s summer freeze often hinges on a critical character: coil temperature. It is the barometer of the system’s health, reflecting the intricate dance between refrigerant, airflow, and environmental conditions. An appropriately cold coil is essential for efficient cooling, drawing heat from the air that passes over it. However, when the coil’s temperature plunges too low, it becomes a catalyst for ice formation, initiating a cascade of problems that ultimately cripple the air handler’s functionality. Consider a scenario where a building owner, striving for optimal energy efficiency, unknowingly sets the thermostat too low during a particularly humid summer. The air handler, working overtime to meet the aggressive temperature target, causes the evaporator coil to become excessively cold. This super-chilled surface then pulls moisture from the already saturated air, leading to a layer of ice that gradually thickens, obstructing airflow and diminishing the system’s cooling capacity.
Maintaining an optimal coil temperature is not merely a matter of preventing ice; it is crucial for ensuring energy efficiency and extending the lifespan of the HVAC system. A coil that is too cold indicates an underlying issue, such as a refrigerant leak, restricted airflow, or a malfunctioning component. Ignoring these warning signs can lead to compressor failure, ductwork damage from condensation, and increased energy consumption as the system struggles to meet the thermostat setting. Take, for instance, a manufacturing plant where the air conditioning system is vital for maintaining consistent product quality. When a minor refrigerant leak causes a drop in coil temperature, operators notice that the air handler is running continuously but failing to maintain the desired temperature. This inefficiency not only increases energy costs but also threatens the integrity of the manufacturing process, potentially leading to production delays and financial losses. A timely diagnosis and repair of the refrigerant leak not only restore the system’s efficiency but also prevent further damage and financial repercussions.
Ultimately, coil temperature serves as a sentinel, alerting operators to potential problems within the air handling system. Monitoring this parameter and understanding the factors that influence it are essential for proactive maintenance and preventing the summer freeze. Whether it’s adjusting thermostat settings, addressing airflow restrictions, or repairing refrigerant leaks, maintaining an optimal coil temperature is crucial for ensuring reliable, efficient cooling throughout the summer months. By recognizing the significance of this seemingly simple parameter, property owners and facility managers can avoid the icy consequences of a system out of balance.
5. Blower Motor
The blower motor, often overlooked, stands as a pivotal figure in the narrative of an air handler freezing up in the summer. It is the workhorse responsible for circulating air across the evaporator coil, the very act that allows the system to absorb heat and cool the designated space. When the blower motor falters, the delicate equilibrium of the HVAC system is disrupted, setting the stage for an icy demise. A failing motor, operating at reduced speed or ceasing function entirely, drastically diminishes the volume of air flowing over the coil. This restricted airflow leads to a disproportionate drop in the coil’s temperature, causing moisture in the air to condense and freeze on the surface. The situation can be likened to a rushing river slowing to a trickle, the chilling effect magnified by the diminished flow. A building manager, facing escalating energy bills and inconsistent cooling, discovered that a neglected blower motor, choked with dust and operating at half-speed, was the root cause of the air handler’s frozen state.
The consequences of a compromised blower motor extend beyond mere ice formation. The reduced airflow forces the compressor to work harder, straining the entire system and potentially leading to premature component failure. The ice itself acts as an insulator, further restricting airflow and exacerbating the problem in a vicious cycle. Consider a hospital where consistent temperature control is paramount for patient comfort and medical equipment performance. A sudden failure of the blower motor triggered a rapid ice buildup on the air handler, causing a significant temperature fluctuation in a critical care unit. The interruption to the cooling system not only jeopardized patient well-being but also threatened the functionality of sensitive medical devices. Regular maintenance and timely replacement of aging blower motors are therefore not mere suggestions; they are essential safeguards for ensuring uninterrupted operation and preventing costly disruptions.
In summation, the blower motor’s role in preventing an air handler from freezing in the summer is undeniable. Its consistent, unimpeded operation is crucial for maintaining the delicate balance of airflow and temperature within the system. Neglecting the blower motor can trigger a cascade of problems, leading to ice formation, system strain, and potentially catastrophic failures. Proactive maintenance, including regular inspections, cleaning, and timely replacements, is the key to preventing this icy crisis and ensuring efficient, reliable cooling throughout the summer months. The blower motor, though often unseen, is a vital protector against the chilling grip of ice within the air handling system.
6. Drainage Issues
The tale of an air handler iced over in the heat of summer often involves a seemingly simple oversight: drainage issues. This aspect, frequently underestimated, plays a crucial role in preventing ice formation. The air conditioning process naturally generates condensation as warm, humid air passes over the cold evaporator coil. This condensation, if not properly drained away, can contribute directly to the problem of a frozen air handler.
-
Clogged Drain Line
The drain line, a conduit for removing condensation, is susceptible to blockage from algae, mold, dust, and other debris. When this line becomes clogged, water backs up into the drain pan. If the pan overflows, the excess moisture can refreeze on the evaporator coil, exacerbating existing ice buildup or initiating it anew. Consider a homeowner who, after a period of heavy AC use, noticed water stains on the ceiling near the indoor unit. Upon inspection, they discovered a clogged drain line and a drain pan overflowing with water, some of which had refrozen on the coil. The blockage had effectively transformed the air handler into its own miniature ice rink.
-
Improper Drain Pan Slope
The drain pan must be properly sloped to facilitate complete drainage. If the pan is uneven or tilted in the wrong direction, water will pool, creating a breeding ground for mold and a constant source of moisture for potential refreezing. Imagine a commercial building where the HVAC system was installed with a slightly misaligned drain pan. Over time, stagnant water accumulated in the low spots, fostering mold growth and providing a continuous supply of moisture that contributed to the air handler’s chronic freezing issues. The improper slope, a seemingly minor installation error, led to persistent problems and costly repairs.
-
Frozen Drain Line
In certain conditions, the drain line itself can freeze, especially if it runs through an unconditioned space or is exposed to cold temperatures. This frozen blockage prevents condensation from escaping, leading to a buildup within the system and eventual ice formation on the evaporator coil. Picture a northern climate where a vacation home’s air conditioning system was left running at a low temperature during the winter months. The condensation slowly trickling through the drain line froze solid, creating a plug that caused the air handler to freeze up completely. The seemingly innocuous act of leaving the AC on resulted in significant damage and costly repairs.
-
Rust and Corrosion
Over time, metal drain pans can rust and corrode, leading to leaks or uneven surfaces that prevent proper drainage. The combination of constant moisture and metal composition creates a conducive environment for degradation, which can exacerbate drainage issues. Imagine an old building where the original drain pan was heavily corroded, creating a non-uniform surface with multiple small leaks. These leaks dripped small amounts of water on other components and some evaporated and made the problem bigger. The corroded drain made a major contributor to the system’s issues.
These drainage issues, whether individually or in combination, can transform a normally functioning air conditioning system into an ice-producing machine. Addressing these concerns through regular maintenance, proper installation, and proactive repairs is crucial for preventing the costly and disruptive consequences of a frozen air handler. The lesson is clear: ensuring proper drainage is not merely an afterthought, it is a vital component of maintaining a healthy and efficient HVAC system.
7. Thermostat Setting
The seemingly simple act of adjusting the thermostat holds surprising power in the narrative of an air handler freezing up during the summer. It’s a lever that, when manipulated without understanding, can unintentionally trigger a cascade of events leading to an icy crisis. While not the sole cause, an inappropriate setting can significantly contribute to the problem, especially when coupled with other pre-existing issues.
-
Aggressively Low Temperature Settings
The pursuit of an arctic chill indoors can backfire. When the thermostat is set to an unrealistically low temperature, the air conditioner operates continuously, relentlessly attempting to reach the unattainable goal. This constant operation can overwork the system, causing the evaporator coil to become excessively cold. In humid climates, this super-cooled coil becomes a magnet for moisture, leading to rapid ice formation. A family, determined to escape the summer heat, set their thermostat to the lowest possible setting. They returned home to find their house still uncomfortably warm and the air handler encased in ice, a direct consequence of their overzealous temperature selection.
-
Short Cycling Amplified by Thermostat Placement
Short cycling, where the air conditioner turns on and off frequently, can be exacerbated by a poorly placed thermostat. If the thermostat is located near a heat source, such as a sunny window or a kitchen appliance, it may prematurely shut off the air conditioner, even if the rest of the house remains warm. This erratic operation can cause the evaporator coil to experience rapid temperature fluctuations, increasing the likelihood of ice formation. A small business owner, frustrated by inconsistent cooling, discovered that the thermostat was positioned directly above a coffee maker. The thermostat, sensing the localized heat, constantly interrupted the cooling cycle, leading to ice buildup and reduced efficiency.
-
Manual vs. Programmable Thermostats and User Behavior
The type of thermostat and user behavior play a significant role. A programmable thermostat, when properly configured, can prevent extreme temperature swings and reduce the risk of ice formation by maintaining a consistent indoor climate. However, manual thermostats, often subject to impulsive adjustments, can contribute to the problem if users frequently crank the temperature down in response to perceived discomfort. A vacation rental property, equipped with manual thermostats, experienced frequent air handler freezing issues due to guests arbitrarily lowering the temperature upon arrival, overwhelming the system’s capacity to cool efficiently.
-
Incorrect Calibration
Sometimes, the thermostat’s temperature readings may be inaccurate due to a calibration problem. If it senses that the air is warmer than it actually is, the air conditioner may run for extended periods, potentially causing the evaporator coil to overcool and freeze. A homeowner, noticing an unusually high energy bill, discovered that their thermostat was consistently reading several degrees higher than the actual indoor temperature. This prompted the air conditioner to run almost constantly, causing the evaporator coil to freeze.
These connections highlight the subtle yet powerful influence of the thermostat setting on the air handler’s performance. While not a direct cause in isolation, an inappropriate setting can exacerbate existing problems or even trigger a freeze when combined with other contributing factors. The thermostat, therefore, should be viewed not merely as a temperature controller but as a critical component in maintaining the overall health and efficiency of the HVAC system, requiring careful consideration and responsible use.
8. Component Failure
The insidious specter of component failure looms large in the narrative of an air handler succumbing to ice in the summer months. It is a testament to the intricate web of interconnected parts, where the malfunction of one can trigger a cascade of events culminating in a system-wide freeze. The air handler, a symphony of carefully calibrated components, relies on the harmonious operation of each element to maintain its delicate equilibrium. When this harmony is disrupted, the consequences can be dramatic. Consider a scenario where a small business owner, struggling to keep pace with rising energy costs, ignored the subtle signs of a failing expansion valve. This valve, responsible for regulating the flow of refrigerant into the evaporator coil, gradually degraded, allowing an uncontrolled surge of refrigerant into the system. The result was an abnormally cold evaporator coil, which rapidly accumulated ice, choking the air handler and crippling its ability to cool. The seemingly minor component failure had brought the entire cooling system to its knees.
The significance of component failure lies not only in its ability to directly cause ice formation but also in its potential to exacerbate other contributing factors. A failing compressor, for example, may struggle to maintain the correct refrigerant pressure, leading to reduced airflow and an increased risk of coil freezing. Similarly, a malfunctioning fan motor can compromise airflow, compounding the problem and accelerating the ice buildup. Imagine a large data center where the continuous operation of the air conditioning system is crucial for preventing equipment overheating. A gradual degradation of the compressor motor resulted in reduced cooling capacity, which was initially masked by the system’s redundancy. However, as the summer heat intensified, the reduced cooling capacity, coupled with the compressor’s increased energy consumption, pushed the system to its limits, eventually causing the air handler to freeze up and threatening the integrity of the entire data center. Timely detection and replacement of the failing compressor could have averted this crisis.
In conclusion, component failure is a significant and often underestimated contributor to air handler freezing in the summer. Its ability to directly cause or exacerbate other contributing factors makes it a critical area of focus for preventative maintenance and timely repairs. By recognizing the subtle signs of component degradation and implementing proactive measures, property owners and facility managers can protect their HVAC systems from the icy grip of failure, ensuring reliable and efficient cooling throughout the hottest months of the year. The key takeaway is clear: vigilance and proactive maintenance are the most effective defenses against the cascading consequences of component failure.
Frequently Asked Questions
These inquiries delve into the perplexing phenomenon of air handlers icing over during warm weather, shedding light on common misconceptions and providing clarity on underlying causes and preventative measures.
Question 1: Why does the air handler form ice during the summer? It seems counterintuitive.
The paradox lies in the process of cooling. Air conditioners extract heat, and if the airflow is insufficient or the refrigerant is low, the evaporator coil becomes too cold. Moisture in the air then freezes on the coil, much like frost forming on a cold windowpane. The irony: the very act of trying to cool creates the ice.
Question 2: Is a frozen air handler merely an inconvenience, or can it cause real damage?
It is more than a nuisance. Untreated, the accumulating ice can damage the evaporator coil itself, potentially leading to costly repairs or replacements. Moreover, the restricted airflow strains other components, such as the compressor, potentially shortening their lifespan. The longer the problem persists, the greater the risk of long-term damage.
Question 3: If I see ice, can I simply defrost it with a hairdryer and consider the problem solved?
While defrosting the coil is a temporary solution, it does not address the underlying cause. Unless the root issue is identified and rectified, the ice will inevitably return. Employing a hairdryer is akin to treating a symptom without diagnosing the disease. A professional assessment is crucial.
Question 4: Are certain types of air conditioning systems more prone to freezing than others?
No particular type is inherently immune. Central air systems, ductless mini-splits, and window units can all experience freezing if conditions are conducive. The vulnerability stems from operational factors and maintenance practices, not the system’s inherent design.
Question 5: My air filter looks relatively clean. Is it still necessary to replace it regularly?
Visual cleanliness can be deceptive. Even a seemingly clean filter can impede airflow, particularly if it is not the correct type or MERV rating for the system. Regular replacement, typically every one to three months, is a preventative measure, regardless of perceived cleanliness. The filter serves as the first line of defense against airflow restrictions.
Question 6: If I suspect a refrigerant leak, is it safe to simply add more refrigerant myself?
Adding refrigerant without addressing the source of the leak is ill-advised and potentially harmful. Its akin to filling a bucket with a hole. Moreover, handling refrigerants requires specialized equipment and knowledge. A professional HVAC technician is essential for locating and repairing the leak and properly recharging the system.
These answers emphasize the complexity of air handler icing and the need for informed action. Addressing the underlying causes, rather than merely treating the symptoms, is crucial for long-term resolution.
The following information will delve into practical steps for troubleshooting and preventing this common HVAC problem.
Preventing the Summer Freeze
The following points offer practical steps, gleaned from years of field experience, to mitigate the risk of an air handler succumbing to ice during the relentless summer months. These are not mere suggestions, but rather time-tested strategies to ensure reliable and efficient cooling.
Tip 1: Implement a Rigorous Filter Replacement Schedule
The tale of many frozen air handlers begins with a neglected filter. Dust and debris accumulate, choking airflow and forcing the system to work harder. Establish a calendar-based reminder to replace filters monthly, or more frequently in dusty environments. Consider it a small investment that yields significant returns in efficiency and longevity.
Tip 2: Schedule Annual Professional HVAC Inspections
The trained eye of an HVAC technician can detect subtle issues before they escalate into major problems. An annual inspection should include a thorough examination of refrigerant levels, ductwork integrity, and component functionality. Think of it as a health checkup for the air conditioning system, catching potential ailments before they become critical.
Tip 3: Ensure Unobstructed Airflow Around the Outdoor Unit
Just as a blocked airway can stifle breathing, obstructed airflow around the outdoor condenser unit hinders its ability to dissipate heat. Clear away any vegetation, debris, or obstructions within a two-foot radius of the unit. This simple act can significantly improve the system’s efficiency and prevent overheating.
Tip 4: Monitor and Address Ductwork Leaks Promptly
Leaky ductwork represents a silent drain on energy efficiency and can contribute to air handler freezing. Seal any visible leaks with appropriate duct tape or mastic sealant. A professional ductwork inspection can identify and address hidden leaks that may be costing money and compromising system performance.
Tip 5: Be Mindful of Thermostat Settings
Avoid setting the thermostat to excessively low temperatures, as this can overwork the system and increase the risk of coil freezing. A moderate and consistent temperature setting is generally more efficient and less stressful on the air conditioning components. Think of it as a marathon, not a sprint, for the air conditioning system.
Tip 6: Maintain proper condensate drain lines
Drain lines are essential for disposing the extra water and humidity from the system. Maintaining drain lines from any clogs is very important and regular maintenance will do wonders.
By adhering to these time-tested strategies, it is possible to safeguard an air conditioning system and prevent the chilling disruption of a summer freeze. Proactive care, rather than reactive repairs, is the key to ensuring reliable and efficient cooling throughout the hottest months.
The final section will bring the insights together and conclude the article.
The Unseen Threat
The investigation into “air handler freezing up in summer” reveals more than just a mechanical malfunction. It exposes a vulnerability, a point of systemic weakness where negligence or ignorance can lead to cascading failures. Each section has detailed potential points of failure, from restricted airflow choking the system to component malfunctions silently undermining its integrity. The narrative is clear: vigilance and proactive maintenance are not optional; they are essential for safeguarding comfort and preventing costly disruptions.
As the summer heat intensifies, remember the lessons learned. The frozen air handler is not merely an inconvenience; it is a symptom of underlying issues that demand attention. Embrace the responsibility of proactive care, schedule regular maintenance, and heed the warning signs. The efficiency and longevity of cooling systems, and perhaps even the stability of operations, depend on it. Let the knowledge gained serve as a catalyst for diligence, ensuring that the chilling grip of ice does not claim the air handlers, and by extension, the summers.